Monday, July 23, 2012

Han® Q Data RJ45 Technical characteristics


Features
  • Combination connector
    - Ethernet connector based on RJ45
    - additionnally maximum 10 signal D-Sub contacts
  • Compact design
  • Crimp termination technology
  • High contact density
  • Turned D-Sub contacts of performance level1*
  • Suitable for hoods and housings of series Han-Compact®

Technical characteristics
Ethernet connector
4, shielded
8, shielded
Terminal RJ45 accd. to IEC 60 603-7 RJ45 accd. to IEC 60 603-7
Wire gauge AWG 24 - 22 flexible AWG 26 - 24 flexible
AWG 23 - 22 solid
Transmission features Cat5e Cat5e
Number of contacts 4, shielded 8, shielded
Control connector
Number of contacts 10
Electrical data
acc. to DIN EN 61 984

5 A   50 V   0.8 kV   3
Rated current 5 A
Rated voltage 50 V
Rated impulse voltage 0.8 kV
Pollution degree 3
Contact resistance > 1010 Ω
Material Polycarbonate
Limiting temperatures - 40 °C ... + 125 °C
Flammability
acc. to UL 94

V 0
Mechanical working life
- mating cycles
 
>
500
* Performance level 1 as per CECC 75 301-802, 500 mating cycles, 10 days 4 mixed gas test as per IEC 60 512


Harting - Top Industrial Connectors Electronic Connectors Manufacturer in German

Han® Q 17 Technical characteristics


Features
  • 17 contact chambers taking the control contacts of the series Han D® (10A)
  • Space-saving and compact design
  • Leading protective ground
  • Crimp terminal with standard Han D® contacts
  • Use of standard tools
  • Insert is suitable for the hoods and housings of the series Han-Compact®
  • The contacts can be removed with the aid of a removal tool from the mating side

Technical characteristics
Specifications
DIN EN 61984
DIN VDE 0110 table 4 / table 2a for clearances and creepage-distances
 
Inserts
Number of contacts 17 + PE
Electrical data
acc. to DIN EN 61 984

10 A   250 V   4 kV   2
Working current 10 A
Working voltage 250 V
Impulse rated voltage 4 kV
Pollution degree 2
Insulation resistance > 1010 Ω
Material Polycarbonate
Temperature range - 40 °C ... + 125 °C
Flammability
acc. to UL 94

V 0
Mechanical working life
- mating cycles
 
>
500
 
Contacts
Material
Copper alloy
Surface
- hard-silver plated
- hard-gold plated
3 µm Ag
2 µm Au over 3 µm Ni
Contact resistance

Crimp terminal
< 3 mΩ
- mm²
- AWG
0,14 - 2,5 mm²
26 – 14
 
Plastic hoods/housings
Material
Polycarbonate RAL 9005
Locking element
Polyamide
Hoods/Housing sealing
NBR
Limiting temperatures
-40 °C / + 125°C
Degree of protection
acc. to DIN EN 60529
for coupled connector


IP 65
Cable gland
Pg16, M25
 

Metal hoods/housings
Material
die cast zinc alloy
Locking element
V2A steel
Hoods/Housing sealing
NBR
Limiting temperatures
-40 °C / + 125°C
Degree of protection
acc. to DIN EN 60529
for coupled connector


IP 65
 
Current carrying capacity
The current carrying capacity is limited by maximum temperature of materials for insert and contacts including terminals. The current capacity-curve is valid for continuous, not interrupted current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60512-5.


(1) Wire gauge 0,5 mm²
(2) Wire gauge 1,0 mm²
(3) Wire gauge 1,5 mm²


Harting - Top Industrial Connectors Electronic Connectors Manufacturer in German

Han® Q 12/0 with PCB adapter Technical characteristics


Features
  • PCB adapter for Han® Q 12/0
  • Robust design
  • Suitable for standard and EMC hoods and housings size Han® 3 A
  • High contact density
  • 12 contacts + PE to the PCB

Technical characteristics
Electrical data
acc. to EN 61 984
7.5 A   250 V   4 kV   3
Rated current 7.5 A
Rated voltage 250 V
Rated impulse voltage 4 kV
Pollution degree 3
Insulation resistance > 1010 Ω
Material Polycarbonate
Limiting temperatures -40 °C ... +125 °C
Flammability acc. to UL 94 V 0

Layout of PCB



Dimensions in mm
Recommended hole diameter: 0.8 mm

Assembly situation



Harting - Top Industrial Connectors Electronic Connectors Manufacturer in German

Han® Q 12/0 Technical characteristics


Features
  • 12 contact chambers taking the control contacts of the series Han D® with crimp termination
  • 1 PE contact with innovative Han-Quick Lock® termination technology
  • 2 coding pins offering 16 coding possibilities
  • Insert suitable for metal and plastic hoods and housings of the series Han® 3 A

Technical characteristics
Specifications
DIN VDE 0627
DIN VDE 0110
DIN EN 61 984
Inserts
Number of contacts 12 + PE
Electrical data acc. to
DIN EN 61 984
10 A 400 V 6 kV 3
Rated current
10 A
Rated voltage
400 V
Rated impulse voltage
4 kV
Pollution degree
3
Pollution degree 2 also 10 A 400/690 V 6 kV 2
Termination Han D® contacts Crimp
Termination PE contact Han-Quick Lock®
Wire gauge PE contact 0.5 – 2.5 mm²
AWG 20 – 14
Insulation resistance > 1010 Ω
Material Polycarbonate
Limiting temperatures -40 °C ... +125 °C
Flammability acc. to UL 94 V 0
Mechanical working life > 500 mating cycles
Contacts
Material Copper alloy
Surface
- hard silver plated 3 μm Ag
- hard gold plated 2 μm Au over 3 μm Ni
Contact resistance < 3 mΩ
Crimp termination
- mm² 0.14 – 2.5 mm²
- AWG 26 – 14
Maximum insilation cross section
- power contacts ø = 5 mm
Plastic hoods/ housings
Material Polycarbonate
Locking element Polyamide
Flammability acc. to UL 94 V 0
Hoods/ housings seal NBR
Limiting temperatures -40 °C ... +125 °C
Degree of protection acc. to
DIN EN 60 529 in locked position
IP 67
Metal hoods/ housings
Material Die cast zinc alloy
Locking element Steel galvanized
Hoods/ housings seal NBR
Limiting temperatures -40 °C ... +125 °C
Degree of protection acc. to
DIN EN 60 529 in locked position
IP 44
IP 67 with sealing screw 09 20 000 9918


Harting - Top Industrial Connectors Electronic Connectors Manufacturer in German

Han® Q 8/0 Quick Lock Technical characteristics


Features
  • Innovative Han-Quick Lock® termination technology
  • Field assembly without special tools
  • Compatible with Han® Q 8/0 standard inserts with crimp terminal
  • Reduced wiring times
  • Insert suitable for plastic hoods and housings of the sizes Han-Compact®
  • Space-saving and compact design
  • Leading protective ground contact

Technical characteristics
Specifications
DIN EN 60 644-1
DIN EN 61 984
Inserts
Number of contacts 8 + PE
Electrical data acc. to
DIN EN 61 984
16 A 500 V 6 kV 3
Rated current 16 A
Rated voltage 500 V
Rated impulse voltage 6 kV
Pollution degree 3
Termination Han-Quick Lock®
Insulation resistance > 1010 Ω
Material insert Polycarbonate
Material seal NBR
Limiting temperatures -40 °C ... +125 °C
Flammability acc. to UL 94 V 0
Mechanical working life > 500 mating cycles
Contacts
Material Copper alloy
Surface
- hard silver plated 3 μm Ag
Contact resistance < 3 mΩ
Han-Quick Lock®
- mm² 0.5 – 2.5 mm²
- AWG 20 – 14
Maximum insilation cross section ø = 3.6 mm
Plastic hoods/ housings
Material Polycarbonate
Locking element Polyamide
Flammability acc. to UL 94 V 0
Hoods/ housings seal NBR
Limiting temperatures -40 °C ... +125 °C
Degree of protection acc. to
DIN EN 60 529 in locked position
IP 65

Current carrying capacity
The current carrying capacity is limited by maximum temperature of materials for insert and contacts including terminals. The current capacity-curve is valid for continuous, not interrupted current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60512-5.
(1) Wire gauge: 0.5 mm²
(2)  Wire gauge: 1.5 mm²
(3)  Wire gauge: 2.5 mm²


Assembly Manual
Remove cable jacket and strip the fine stranded wires


Push fine stranded wires into the Han-Quick Lock® contact and push the blue slide with a screw driver1) until it comes to a stop


Removal Manual
Please insert the screw driver1) at an angle of 45° into the opening and lever the blue slide out

1) Screw driver: 0.4 x 2.5 mm or 0.5 x 3.0 mm