Han® Q 5/0 Specifications


Features
  • 5 contact chambers for the power contacts of the series Han E® (16 A)
  • Space-saving and compact design
  • Leading protective ground with Screw terminal
  • Crimp terminal with standard Han E® contacts
  • Use of standard tools
  • Compatible with metal and plastic hoods of the series Han® 3 A / 4 A
  • The contacts can be removed with the aid of a removal tool from the termination side
  • Degree of protection IP 65 2)
Specifications
DIN VDE 0627 Connectors and plug-and-socket devices
DIN VDE 0110 table 4/table 2a for clearances and creepage-distances
DIN EN 61984
Approvals
,
 
Inserts
Number of contacts 5 + PE
Electrical data
acc. to DIN EN 61 984

16 A   230 / 400 V   4 kV   3
Working current 16 A
Working voltage conductor - ground 230 V
Working voltage conductor - conductor 400 V
Rated impulse voltage 4 kV
Pollution degree 3
- Pollution degree 2 also 16 A   320 / 500 V  4 kV   2
Working voltage
acc. to UL/ CSA
 
600 V
Working voltage for
wrap terminal acc. to CSA

2 A   30 V
Insulation resistance > 1010 Ω
Material Polycarbonate
Temperature range - 40 °C ... + 125 °C
Flammability
acc. to UL 94

V 0
Mechanical working life
- mating cycles
 
>
500
 
Contacts
Material
Copper alloy
Surface
- hard-silver plated
- hard-gold plated
3 µm Ag
2 µm Au over 3 µm Ni
Contact resistance
< 1 mΩ
Crimp terminal
- mm²
- AWG
0,5 - 2,5 mm²
20 – 14
 
Plastic Hoods/Housings
Material
Polycarbonate
RAL 7032
Locking element
Polyamide
RAL 7032
Flammability
acc. to UL 94

V 0
Hoods/Housings seal
NBR
Limiting temperatures
-40 °C / + 125°C
Degree of protection
acc. to DIN EN 40050
for coupled connector


IP 651)
 
Metal Hoods/Housings
Material
die cast zinc alloy
Locking element
steel, galvanized
Hoods/Housings seal
NBR
Temperature range
- 40 °C...+ 125 °C
Degree of protection
acc. to DIN EN 40050
for coupled connector


IP 44 1)
1) without washer
2) IP 65 will be achieved with sealing screw
 
Current carrying capacity
The current carrying capacity is limited by maximum temperature of materials for insert and contacts including terminals. The current capacity-curve is valid for continuous, not interrupted current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60512-5.
Working current


Ambient temperature
(1) Wire gauge 2,5 mm²
(2) Wire gauge 1,5 mm²