Technical characteristics har-bus® HM
Design according | IEC 61 076 - 4 - 101 |
Approvals | |
Underwriters
Laboratories Inc.® |
with their respective ratings documented in file E 102079 |
Number of contacts | 55 – 220 signal (77 – 308 fully shielded); or customised |
Contact spacing | 2.00 mm |
Working current | 1 A @ 70 °C (80 % derating) |
Test voltage Ur.m.s. | AC 750 V min. |
Contact resistance
|
20 mΩ max.
|
Insulation resistance | 10 GΩ min. |
Temperature range | – 55 °C … + 125 °C |
| |
Durability as per IEC 61076-4-101 |
Performance level 2 = 250
mating cycles in total.
First 125 mating cycles, then 4 days gas test using 0.5 ppm SO2 and 0.1 ppm H2S (at 25 ± 2 °C and 75 ± 3 % humidity). Measurement of contact resistance. The remaining 125 mating cycles are subject to measurement of contact resistance and visual inspection. No abrasion of the contact finish through to the base material. No functional impairment. |
Performance level 1 = 500 mating cycles in total. First 250 mating cycles, then 10 days gas test using 0.5 ppm SO2 and 0.1 ppm H2S (at 25 ± 2 °C and 75 ± 3 % humidity). Measurement of contact resistance. The remaining 250 mating cycles are subject to measurement of contact resistance and visual inspection. No abrasion of the contact finish through to the base material. No functional impairment. | |
Termination technique | compliant press-in |
Mating force | 0.75 N/pin max. |
Withdrawal force | 0.15 N/pin min. |
Materials | |
Mouldings | Thermoplastic resin, glass-fibre filled, UL 94-V0 |
Contacts | Copper alloy |
Contact surface | |
Contact zone male | Au/PdNi/Ni, contacts are treated with Bellcore recommended lubricant (PPE) |
Contact zone female | Au/Ni, contacts are treated with Bellore recommended lubricant (PPE) |
Press-in zone | Ni |
Packaging | Tube |