Monday, July 23, 2012

Han® Q 4/2 Axial screw Technical characteristics


Features
  • Field assembly without special tools
  • Compatible with Han® Q 4/2 standard inserts with crimp terminations
  • Reduced wiring times
  • Inserts suitable for standard plastic and metal hoods/housings with additional PE contact from the Han-Compact® size
  • Space-saving and compact design
  • With or without Han-Quick Lock® signal contacts as an option
Attention
  • For termination please use only hexagonal screw driver with wrench size SW 2.
  • If PE contact is not used: Please screw the PE contact maximal on both sides clockwise with a hexagonal screwdriver, wrench size SW 2.


Technical characteristics
Specifications
DIN EN 60 644-1
DIN EN 61 984
Inserts
Number of contacts 4/2 + PE
Electrical data acc. to
DIN EN 61 984
Power area
40 A 400/690 V 6 kV 3
Rated current 40 A
Rated voltage conductor - ground 400 V
Rated voltage conductor - conductor 690 V
Rated impulse voltage 6 kV
Pollution degree 3
Signal area
10 A 250 V 4 kV 3
Rated current 10 A
Rated voltage 250 V
Rated impulse voltage 4 kV
Pollution degree 3
Insulation resistance > 1010 Ω
Material insert Polycarbonate
Material seal NBR
Limiting temperatures -40 °C ... +125 °C
Flammability acc. to UL 94 V 0
Mechanical working life
- mating cycles
> 500
Contacts
Material Copper alloy
Surface
- hard silver plated 3 μm Ag
Power contacts
Contact resistance < 0.3 mΩ
Axial screw termination
- mm² 4 ... 10 mm²
- AWG 12 ... 8
max. Insulation cross section 5 mm
Stripping length 8 mm+1
max.Tightening tourque 1.8 Nm
Signal contacts
Contact resistance < 3 mΩ
Han-Quick Lock®
- mm² 0.25 ... 1.5 mm²
- AWG 23 ... 16
max. Insulation cross section 3 mm
Stripping length 10 mm+1
Hoods / housings
Material plastic Polycarbonate
Material metal Zinc die-cast
Flammability acc. to UL 94 V 0
Hoods/ housings seal NBR
Limiting temperatures -40 °C ... +125 °C
Degree of protection acc. to
DIN EN 60 529 in locked position
IP 65

Current Carrying Capacity
The current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-intermittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.
Measuring and testing techniques according to DIN EN 60 512-5.


(1) Wire gauge: 4 mm²
(2) Wire gauge: 6 mm²


Harting - Top Industrial Connectors Electronic Connectors Manufacturer in German

Han® Q 4/2 Technical details Specifications


Features
  • 2 power contacts Han D® 10 A
    4 signal contacts Han® C 40 A
  • Leading protective ground
  • Protection against contact with the fingers acc. to IEC 60 529
  • Insert is suitable for the hoods and housings of the series Han-Compact® (not suitable for 19 12 008 0501)
  • The power contacts can be removed with the aid of a removal tool from the termination side
  • 3 coding possibilities by using a coding pin instead of the fixing screw

Technical details
Specifications
DIN VDE 0627 Connectors and plug-and-socket devices
DIN VDE 0110 table 4/table 2a for clearances and creepage-distances
DIN EN 61 984
Inserts
Number of contacts 4/2 + PE
Electrical data
acc. to DIN EN 61 984

40 A   400/690 V   6 kV   3
Working current 40 A
Working voltage 400 / 690 V
Rated impulse voltage 6 kV
Pollution degree 3
Insulation resistance > 1010 Ω
Material Polycarbonate
Temperature range - 40 °C ... + 125 °C
Flammability
acc. to UL 94

V 0
Mechanical working life > 500 mating cycles
Han® C Contacts (Power contacts)
Material
Copper alloy
Surface
- hard-silver plated
5 µm Ag
Contact resistance
< 1 mΩ
Crimp terminal
- mm²
- AWG
2,5 - 6 mm²
14 - 10
Max. Insulation diameter
of single strand
5 mm

Plastic hoods/housings
Material
Polycarbonate RAL 9005
Locking element
Polyamide RAL 9005
Flammability acc. to UL 94
V 0
Hoods/Housing seal
NBR
Limiting temperatures
-40 °C / + 125°C
Degree of protection
acc. to DIN EN 60529
for coupled connector


IP 65
 
 
Current carrying capacity
The current carrying capacity is limited by maximum temperature of materials for insert and contacts including terminals. The current capacity-curve is valid for continuous, not interrupted current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60512-5.

Wire gauge:
1= 2,5 mm²
2= 4 mm²
control contacts not under load


Harting - Top Industrial Connectors Electronic Connectors Manufacturer in German

Han® Q 2/0 High Voltage Connector for Single Phase Application



Features
  • Compact design
  • 16 coding options
  • For hoods/housings size Han® 3 A
  • Axial screw terminal
  • For high voltages please use heat shrink tube (included in delivery range)
Attention!
For termination please use only hexagonal screw driver with wrench size 2.
 

Technical Characteristics

Electrical data
acc. to DIN EN 61 984

40 A   830 V   8 kV   3
Working current 40 A
Working voltage 830 V
Rated impulse voltage 8 kV
Pollution degree 3
Wire gauge 4 to 6 mm²
(10 mm² optional)
or 2.5 to 6 mm²
Tightening torque 1,8 Nm
Insulation resistance > 1010 Ω
Material Polycarbonate
Flammability
acc. to UL 94

V 0
Mechanical working life > 500 mating cycles


Harting - Top Industrial Connectors Electronic Connectors Manufacturer in German

Han® Q 2/0 Crimp High Voltage Technical characteristics


Features
  • High current rated compact designed connector for hoods/housings size Han® 3 A
  • Mating compatible to the axial screw version with 16 coding options
  • Using of standard Han C crimp contacts and crimp tools wich allows a cost optimised production of high quantities
  • For high voltages, please use heat shrink tube
  • Finger protected male and female contacts
  Remark
• By using in Han® 3 A HPR hoods/housings the sealing on the insert has to be removed.

Technical characteristics
Inserts
Number of contacts 2 + PE
Electrical data
acc. to EN 61 984
40 A 830 V 6 kV 3
Rated current 40 A
Rated voltage 830 V
Rated impulse voltage 6 kV
Pollution degree 3
Insulation resistance  > 1010 Ω
Material polycarbonate
Limiting temperatures -40 °C ... 125 °C
Flammability acc. to UL 94 V 0
Mechanical working life
- mating cycles > 500
Contacts
Material copper alloy
Surface
- hard-silver plated 3 μm Ag
Contact resistance  ≤ 1 mΩ
Crimp termination
- mm² 1.5 ... 10 mm²
- AWG 16 ... 8
Tools
see chapter 99 in the main catalogue „Industrial Connectors Han®“
Hoods/Housings
Selection of hoods/housings see Han® main catalogue chapter 30 / chapter 31
Plastic hoods/housings
Material polycarbonate
Flammability acc. to UL 94 V 0
Degree of protection
acc. to DIN EN 60 529
for coupled connector
IP 67
Metal hoods/housings
Material zinc die-cast
Degree of protection
acc. to DIN EN 60 529
for coupled connector
IP 44
IP 67 is achieved with seal screw 09 20 000 9918

Current Carrying Capacity
The current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-intermittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.
Measuring and testing techniques according to DIN EN 60 512-5



(1) wire gauge: 2.5 mm²
(2) wire gauge: 4 mm²
(3) wire gauge: 6 mm²
(4) wire gauge: 10 mm²


Harting - Top Industrial Connectors Electronic Connectors Manufacturer in German

Han® Q 2/0 Crimp Technical characteristics


Features
  • High current rated compact designed connector for hoods/housings size Han® 3 A
  • Mating compatible to the axial screw version with 16 coding options
  • Using of standard Han C crimp contacts and crimp tools wich allows a cost optimised production of high quantities
  • Finger protected male and female contacts
  Remark
  • By using in Han® 3 A HPR hoods/housings the sealing on the insert has to be removed.

Technical characteristics
Inserts
Number of contacts 2 + PE
Electrical data
acc. to EN 61 984
40 A 400 V 6 kV 3
Rated current 40 A
Rated voltage 400 V
Rated impulse voltage 6 kV
Pollution degree 3
Insulation resistance  > 1010 Ω
Material polycarbonate
Limiting temperatures -40 °C ... 125 °C
Flammability acc. to UL 94 V 0
Mechanical working life
- mating cycles > 500
Contacts
Material copper alloy
Surface
- hard-silver plated 3 μm Ag
Contact resistance  ≤ 1 mΩ
Crimp termination
- mm² 1.5 ... 10 mm²
- AWG 16 ... 8
Tools
see chapter 99 in the main catalogue „Industrial Connectors Han®“
Hoods/Housings
Selection of hoods/housings see Han® main catalogue chapter 30 / chapter 31
Plastic hoods/housings
Material polycarbonate
Flammability acc. to UL 94 V 0
Degree of protection
acc. to DIN EN 60 529
for coupled connector
IP 67
Metal hoods/housings
Material zinc die-cast
Degree of protection
acc. to DIN EN 60 529
for coupled connector
IP 44
IP 67 is achieved with seal screw 09 20 000 9918

Current Carrying Capacity
The current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-intermittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.
Measuring and testing techniques according to DIN EN 60 512-5



(1) wire gauge: 2.5 mm²
(2) wire gauge: 4 mm²
(3) wire gauge: 6 mm²
(4) wire gauge: 10 mm²


Harting - Top Industrial Connectors Electronic Connectors Manufacturer in German